USER MANUAL PREMIER & ULTRA SERIES
CONTROL PANEL LAYOUT
VACUUM
GASFLUSH
SEAL
SOFT-AIR
STOP
VAC
STOP
-1
0
0,2
0,4
0,6
0,8
1. Small Display
Displays active program in operating and program modes.
2. Large Display
Displays the current value of the active function during the program cycle or the set value of the selected function in operation or
program mode.
3. PROG 0-9 Keys
Selects program number in operation or program mode.
4. REPROG Key
Switch from operation mode to program mode (for setting function values) and vice versa. After setting new function value(s)
within a selected program in program mode, this key must always be used to store the new values for the program in memory.
5. FUNCTION SELECT Key
Selects function within selected program in operation and program mode. The function is selected if the function light is
on in front of the function description under the large display.
6. CONDITIONING PROGRAM Key
Start the conditioning program for pump (duration 15 minutes). For instructions on the program, see page 19.
7. FUNCTION Lights
A light in front of the function indicates that the function is active during the program cycle or that the function is selected during
the operation or program modes.
Special Remark: There is an additional time operated vacuum function available at digital sensor control, the
VACUUM PLUS function. This function is not displayed on the panel. The VACUUM PLUS function
can only be activated if the standard vacuum function is set to 99% VACUUM PLUS function
display during the cycle (if activated) : The vacuum indicator light remains on after 99% is reached
and during the time set for VACUUM PLUS. During the VACUUM PLUS vacuum cycle a dot
appears in the right lower corner of the large display. Display during operation and program mode :
If the VACUUM PLUS time is activated during the selected program then a dot appears in the lower
right-hand corner of the large display during the operation and program mode. If the functions are
selected using the function selection keys then the indicator light in front of VACUUM comes on
twice, and the vacuum percentage and VACUUM PLUS time are shown consecutively.
Special Remark If the machine has the gas ush function implemented and the function is activated within the
selected program then a dot appears in the lower right hand corner of the small display when
selecting the program no..
8. + / STOP VACUUM Key
Function during cycle Interruption of the active function during the program cycle. The cycle immediately continues with
the next function.